Applications:
Use with all liquid and gas medias that are not corrosive to stainless steel, non-crystallizing, and not highly viscous
Glycerin/silicon oil filled type for measuring points subject to vibrational and highly dynamic pressure loads (chemical, petrochemical, food, and biochemistry industries
Specifications:
Dial diameters:
1 1/2-inch (40mm), 2-inch (50mm), 2 1/2-inch (63mm), 3-inch (75mm), 4-inch (100mm), and 6-inch (150mm)
Case:
304 stainless steel IP65 crimp bezel for dial, £X1 1/2 to 4 inches ,Bayonet bezel for dial £X2 1/2 to 6-inch
Lens:
acrylic or glass for dial 1 1/2 to 4-inch, safety glass for dial ;4, and 6-inch
Dial:
aluminum, black, and red markings on white background, dial arc 270;
Measuring principle:
Bordon tube, 316 stainless steel C form tube for ¡Ø70kg/cm1
Helical form tube for ¡Ö70kg/cm2
Movement:
stainless steel
Pointer:
aluminum, black, adjustable pointer available for dial ;4 and 6 inches
Connection:
male thread 1/8, 1/4, 3/8, 1/2-inch PT (BSPT)/NPT/PF (BSP), 316 stainless steel
Filling:
without (dry), glycerin filled, or silicon oil filled
Accuracy:
¡Ó2% F.S. for ;1 1/2 and 2-inch, ¡Ó1.5% F.S. for ;2 1/2 and 3-inch, ¡Ó1% FS for ;4 and 6 inches
Temperature limits:
dry-medium +200¢J, ambient -20 to +60¢J
Glycerin filled:
medium +60¢J, ambient 10 to 60¢J
Silicon oil filled:
medium +100¢J, ambient -45 to +60¢J
Silicon oil filled type can be for medium +200¢J only if the case and connection are welded together (argon-arc welding), available for £X2 1/2, 4, and 6 inches
Ranges:
Positive: 0/1 to 0/1,000kg/cm2
Negative 0/76cmHg (relative vacuum)
Compound -76cmHg/0/1 to -76cmHg/ 0/20kg/cm2
Other units available: p
si, bar, and MPa