Ashly NXE3.04 Specs
Channels 4
Maximum Output Power Max Output Power Per Channel, Low Impedance Output, All Channels Driven
2 Ohms: 3000 W, 4 Ohms: 2000 W, 8 Ohms: 1250 W
Low Impedance Output, Bridge Mode, All Channels Driven
4 Ohms: 6000 W
8 Ohms: 4000 W
70 V, 100 V Output, All Channels Driven
70 V (per channel): 2450 W
100 V (per channel): 1250 W
Power Draw Total Power Draw All Channels Driven
Sleep Mode: <1 W
Standby Mode: 70 W
Idle (no signal): 100 W
Current Draw Current Draw 120 VAC Mains (divide in half for 240 V)
Sleep Mode: 0.1 A
Standby Mode: 1.3 A
Idle (no signal): 1.85 A
Maximum Current Draw All Channels Driven, Divide by 2 for 240 VAC
1/8 Maximum Power @ 2 Ohms: 29.5 A
Dissipation Thermal Dissipation BTU/hr, Total for All Channels Driven
Sleep Mode: <3.4
Standby Mode: 238 BTU/hr
Idle (no signal): 340 BTU/hr
1/8 Maximum Power @ 2 Ohms: 2720 BTU/hr
Voltage Gain Selectable at 26 dB, 32 dB, 38 dB, or 1.4 V
Damping Factor >250 (8 Ohms load <1 kHz)
High Pass Filter Input: 80 Hz 2nd order
Distortion SMPTE, typical: <0.5%
THD-N, typical: <0.5% (8 Ohms, 10 dB below rated power, 20 Hz to 20 kHz)
Channel Separation -75 dB (dB from full output, 1 kHz)
Signal-to-Noise Ratio 20 Hz to 20 kHz, Unweighted: >114 dB
Frequency Response 20 Hz to 20 kHz, +/-0.05 dB
Input Connector Balanced: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
Input Impedance 10 kOhms
Maximum Input Level +21 dBu
Output Connector Speaker: Neutrik speakON
AUX: Balanced Euroblock 3.5 mm
Network Control Network: Compatible with standard 100 MB Ethernet
Aux Output Level Maximum: +21 dBu
Contact Closure Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode
Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
Supported Data Connections Euroblock 3.5 mm - Gnd, +18 V, In, Out
Logic Output Fault Condition: Euroblock 3.5 mm - 4 available
Level Control Remote DC: Euroblock 3.5 mm - Gnd, CV, V+ per input
Active Attenuators Per Channel: Front panel, software, offset link group, and remote
Fully Off: Mute
Amplifier Protection Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
Cooling Continuously variable temperature controlled axial fan(s)
Environmental 32 to 113°F (0 to 45°C) (non-condensing)
Front Panel LED Indicators POWER (white): Switch: On, Off, Standby (flashing)
PROTECT (red): On (fault condition or shut down), Off
SLEEP (blue): On, amplifier is asleep from audio inactivity
DISABLE (yellow): On, power switch & front panel attenuators are disabled
Per Channel
CLIP/MUTE (red): Clip @ 1 dB below full output / Mute
SIGNAL (green): -18 dB below rated output
CURRENT (green): Proportional to output
TEMP (yellow): On dim at 90% max operating temperature, full bright + protect at 100%
BRIDGE (green): On, Off
Power Requirements @ 50/60 Hz
Nominal (Automatic Sensing SMPS): 120 to 240 VAC
Operating Range: 70 to 135 VAC to 140 to 270 VAC
Minimum Power-Up: 85 to 170 VAC
Power Cable Connector: 20 A powerCON
Compliance cTUVus, CE, FCC, RoHS
Dimensions 19 x 3.5 x 16.84 (483 x 89 x 428 mm)
Weight 28.7 lb (13 kg)